Honeywell
📢 100% genuine, extensive in-stock inventory, fast shipping!
Honeywell 05704-A-0144 System 57 Four-Channel Control Card
Honeywell 05704-A-0144 System 57 Four-Channel Control Card
Manufacturer: Honeywell
-
Product No.: 05704-A-0144
Condition:in Stock
Product Type: Four-Channel Control Card
-
Product Origin: USA
Payment:T/T, Western Union
-
Weight: 2000g
Shipping port: Shanghai/Yiwu/Shenzhen
Warranty: 12 months
Share
Product Description
Overview
The Honeywell 05704-A-0144 is a four-channel control card designed for the System 57 gas detection network. It provides centralized monitoring for up to four individual gas sensors, converting analog signals into actionable data for industrial safety systems. This module combines precision signal processing, robust fault detection, and user-friendly calibration in a compact, rack-mountable format.
Key Features
Multi-Channel Gas Monitoring
-
Supports four independent sensor inputs, including catalytic bead (flammable) and 4–20 mA (toxic or oxygen) signals
-
Reduces system complexity and saves rack space
Advanced Alarm and Fault Logic
-
Provides three configurable alarm levels per channel (A1, A2, A3)
-
Dedicated fault detection for sensor failure, short circuit, or open circuit
-
Electronic adjustment of bridge balance and signal gain
Precision Signal Handling
-
Full-scale signal range: 15 mV to 300 mV
-
Electronic current adjustment from 90 to 315 mA in 1 mA increments
-
Maximum drive voltage: 10 V, maximum line resistance: 40 ohms at 200 mA
-
Initial measurement accuracy: ±1%
User-Friendly Interface and Calibration
-
Multi-segment backlit LCD for real-time gas readings, channel status, and analog bar display
-
One-person calibration supported via front panel or engineering tool
Industrial Reliability
-
EMI/RFI shielding for high-noise environments
-
Rack-mountable design compatible with all System 57 components
-
Maximum power consumption: 12.8 W (200 mA sensor current), typical 8.5 W
Applications
-
Industrial gas detection in refineries, chemical plants, and confined spaces
-
Multi-zone monitoring for flammable, toxic, or oxygen-deficient environments
-
Integration with System 57 racks and safety networks
Technical Specifications
| Feature | Specification |
|---|---|
| Model Number | 05704-A-0144 |
| Manufacturer | Honeywell |
| Channels | 4 |
| Sensor Type | Catalytic Bead or 4–20 mA |
| Display | Multi-character backlit LCD with Bar Graph |
| Current Drive | Electronic, 90–315 mA in 1 mA steps |
| Maximum Drive Voltage | 10 V |
| Full-Scale Signal | 15–300 mV |
| Bridge Imbalance | ±100 mV from center at 2 V bridge voltage |
| Fault Detection | Open Circuit, Short Circuit, Single Bead Failure |
| Power Consumption | 8.5 W typical, 12.8 W maximum |
| Mounting | System 57 Rack |
| Shipping Weight | 2 kg |
| Protection | Short Circuit and Open Circuit Protected |
FAQ
Q: Can the 05704-A-0144 card handle both flammable and toxic sensors?
A: Yes, it is compatible with catalytic bead (flammable) and 4–20 mA (toxic or oxygen) sensors.
Q: How is the card calibrated?
A: Calibration can be performed by one technician using the front panel or an engineering tool, reducing downtime.
Q: What is the expected installation lead time?
A: Estimated lead time is 6–8 weeks from order confirmation.
Q: Can this card replace other System 57 modules?
A: Replacement is only recommended if the model and part number (05704-A-0144) match to ensure proper alarm and signal processing.