Honeywell
📢 100% genuine, extensive in-stock inventory, fast shipping!
Honeywell 51202329-600 Gray Header I/O Link Cable
Honeywell 51202329-600 Gray Header I/O Link Cable
Manufacturer: Honeywell
-
Product No.: 51202329-600
Condition:in Stock
Product Type: Gray Header I/O Link Cable
-
Product Origin: USA
Payment:T/T, Western Union
-
Weight: 600g
Shipping port: Shanghai/Yiwu/Shenzhen
Warranty: 12 months
Share
Honeywell 51202329-600 Gray Header I/O Link Cable
The Honeywell 51202329-600, also cataloged as the 51202329 gray header I/O link cable, serves as a structured signal distribution component for Series C Distributed Control System (DCS) architectures.
Part Number Breakdown
- Model (51202329): Series C I/O Link cable
- Suffix (600): Gray header cable variant
- Design: 3 drops with 6 in (152 mm) pitch spacing
- Weight: Approximately 60 g
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 51202329-600 |
| Brand | Honeywell |
| Origin | USA |
| Weight | ~60 g |
| Dimensions | 3 drops; 6 in (152 mm) pitch spacing |
| Operating Temp | Matches standard industrial cabinet enclosure limits |
| Power Consumption | Passive cable |
| Core Performance | Gray header identification; redundant bidirectional communication; Series C DCS compatibility |
Channel-to-Channel Isolation and Redundant Connectivity
The gray header cable supports dual-channel redundant communication within Honeywell Experion PKS Series C systems. Three discrete drops provide structured connectivity to I/O modules, while gray jacket coloration ensures clear identification in cabinet layouts. Shield continuity and grounding practices suppress induced noise, maintaining stable signal transmission across distributed control assemblies.
Frequently Asked Questions
Q: Can the 51202329-600 cable be used interchangeably with violet drop cables? A: No. Violet drop cables are designated as Cable B, while gray header cables serve as header interconnects.
Q: What is the recommended pitch spacing for installation? A: Maintain the 6 in (152 mm) pitch spacing between drops to preserve alignment and mechanical integrity.
Q: Does the cable require special certification for use in standard enclosures? A: No. It is CE certified and designed for standard industrial cabinet environments.
Field Installation Guidelines
- Assign gray header cables correctly in Series C layouts; use jacket color for identification.
- Route cables separately from high-voltage conductors to minimize EMI.
- Ground shielding at the controller end only to prevent ground loop currents.
- Verify continuity and drop assignment during commissioning with loop test equipment.
- Maintain bend radius within manufacturer specifications to protect conductor insulation.