Honeywell
📢 100% genuine, extensive in-stock inventory, fast shipping!
Honeywell 51202329-614 Series C I/O Link Cable
Honeywell 51202329-614 Series C I/O Link Cable
Manufacturer: Honeywell
-
Product No.: 51202329-614
Condition:in Stock
Product Type: Violet Drop Cable
-
Product Origin: USA
Payment:T/T, Western Union
-
Weight: 300g
Shipping port: Shanghai/Yiwu/Shenzhen
Warranty: 12 months
Share
Honeywell 51202329-614 Series C I/O Link Cable
The Honeywell 51202329-614, also cataloged as the 51202329 Series C I/O link cable, operates as Cable A for structured communication between Honeywell Experion PKS and TDC 3000 distributed control systems.
Specifications
| Parameter | Specification |
|---|---|
| Model | 51202329-614 |
| Brand | Honeywell |
| Origin | USA |
| Weight | 0.2–0.3 kg |
| Shipping Weight | ~3.0 kg |
| Dimensions | 3 drops; 6 in (152 mm) pitch spacing |
| Operating Temp | Matches standard industrial cabinet enclosure limits |
| Power Consumption | Passive cable |
| Core Performance | Violet header; yellow label (Cable A); bidirectional digital transmission; CE certified |
| System Compatibility | Honeywell Experion PKS / TDC 3000 DCS |
| Protocol | Honeywell proprietary I/O Link communication |
| Topology | Daisy-chain physical network layout |
| Connection Drops | 3 drops for Series C I/O modules |
| Signal Support | Bidirectional digital transmission of process control, diagnostics, and module health |
Channel-to-Channel Isolation and Redundant Connectivity
The cable supports dual redundant communication paths in Series C architectures. Three discrete drops provide structured connectivity to I/O modules, while violet jacket coloration ensures clear identification in cabinet layouts. Yellow label coding designates Cable A, paired with Cable B for redundancy. Shield continuity and grounding practices suppress induced noise, maintaining stable signal transmission across distributed control assemblies.
Frequently Asked Questions
Q: Can the 51202329-614 cable be used independently without Cable B? A: Yes, but for redundant communication, Cable A must be paired with Cable B.
Q: What is the recommended installation spacing? A: Maintain the 6 in (152 mm) pitch spacing between taps to preserve alignment and mechanical integrity.
Q: Does the cable support diagnostics transmission? A: Yes. It supports bidirectional transmission of process control, diagnostics, and module health statuses.
Field Installation Guidelines
- Assign Cable A correctly in redundant channel mapping; use yellow labels for identification.
- Route drop cables separately from high-voltage conductors to minimize EMI.
- Ground shielding at the controller end only to prevent ground-loop currents.
- Verify continuity and drop assignment during commissioning with loop test equipment.
- Maintain bend radius within manufacturer specifications to protect conductor insulation.