Honeywell
📢 100% genuine, extensive in-stock inventory, fast shipping!
Honeywell 8C-TAIX51 51306979-175 Digital Input Module
Honeywell 8C-TAIX51 51306979-175 Digital Input Module
Manufacturer: Honeywell
-
Product No.: 8C-TAIX51 51306979-175
Condition:in Stock
Product Type: Digital Input Module
-
Product Origin: USA
Payment:T/T, Western Union
-
Weight: 260g
Shipping port: Shanghai/Yiwu/Shenzhen
Warranty: 12 months
Share
Honeywell 8C-TAIX51 Digital Input Module
The Honeywell 8C-TAIX51, also cataloged as the 51306979-175 Digital Input Module, serves as a Series 8 I/O termination assembly for acquiring differential signals and integrating bidirectional HART communication within Experion PKS and C300 networks.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 8C-TAIX51 |
| Brand | Honeywell |
| Channels | 16 differential input channels |
| Signal Range | 4–20 mA DC, 0–10 VDC, ±10 V |
| Protocol | Integrated bidirectional HART |
| Resolution | 16-bit A/D converter |
| Accuracy | ±0.1% of full scale |
| Update Rate | 250 ms typical |
| Nominal Supply | 24 VDC |
| Power Consumption | 2.8 W max |
| Isolation | 1500 VDC channel-to-backplane |
| Operating Temp | -40 to +70 deg C |
| Humidity | 5%–95% RH non-condensing |
| Dimensions | 118 mm × 31 mm × 140 mm |
| Weight | 0.26 kg |
| System Integration | Experion PKS, Series 8, C300 |
4-20 mA HART Loop Protocol
The 8C-TAIX51 supports 4-20 mA HART loop protocol, enabling simultaneous analog measurement and digital communication. This ensures parameter interrogation and diagnostics without interrupting process signals. Channel-to-channel isolation prevents interference across loops, maintaining deterministic input performance.
Frequently Asked Questions
Q: Can the 8C-TAIX51 be hot-swapped in Series 8 racks? A: Yes, the module supports removal and installation under power (RIUP) within Series 8 IOTA assemblies.
Q: What is the maximum backplane isolation rating? A: The module provides 1500 VDC isolation between channels and backplane circuitry.
Q: Does the module require firmware updates? A: Firmware is managed at the controller level; the input module itself does not require independent updates.
Field Installation Guidelines
- Ensure shielded cabling for analog loops to minimize EMI.
- Maintain separation of digital and analog wiring to reduce cross-talk.
- Verify DIN rail mounting stability before energizing.
- Observe environmental limits of -40 to +70 deg C and 5%–95% RH non-condensing.
- Confirm proper backplane connector alignment to avoid bent pins.