Skip to product information
1 of 2

Honeywell

📢 100% genuine, extensive in-stock inventory, fast shipping!

Honeywell 8C-TAIX51 51306979-175 Digital Input Module

Honeywell 8C-TAIX51 51306979-175 Digital Input Module

  • Manufacturer: Honeywell

  • Product No.: 8C-TAIX51 51306979-175

  • Condition:in Stock

  • Product Type: Digital Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 260g

  • Shipping port: Shanghai/Yiwu/Shenzhen

  • Warranty: 12 months

Honeywell 8C-TAIX51 Digital Input Module

The Honeywell 8C-TAIX51, also cataloged as the 51306979-175 Digital Input Module, serves as a Series 8 I/O termination assembly for acquiring differential signals and integrating bidirectional HART communication within Experion PKS and C300 networks.

Hardware Specifications

Parameter Specification
Model 8C-TAIX51
Brand Honeywell
Channels 16 differential input channels
Signal Range 4–20 mA DC, 0–10 VDC, ±10 V
Protocol Integrated bidirectional HART
Resolution 16-bit A/D converter
Accuracy ±0.1% of full scale
Update Rate 250 ms typical
Nominal Supply 24 VDC
Power Consumption 2.8 W max
Isolation 1500 VDC channel-to-backplane
Operating Temp -40 to +70 deg C
Humidity 5%–95% RH non-condensing
Dimensions 118 mm × 31 mm × 140 mm
Weight 0.26 kg
System Integration Experion PKS, Series 8, C300

4-20 mA HART Loop Protocol

The 8C-TAIX51 supports 4-20 mA HART loop protocol, enabling simultaneous analog measurement and digital communication. This ensures parameter interrogation and diagnostics without interrupting process signals. Channel-to-channel isolation prevents interference across loops, maintaining deterministic input performance.

Frequently Asked Questions

Q: Can the 8C-TAIX51 be hot-swapped in Series 8 racks? A: Yes, the module supports removal and installation under power (RIUP) within Series 8 IOTA assemblies.

Q: What is the maximum backplane isolation rating? A: The module provides 1500 VDC isolation between channels and backplane circuitry.

Q: Does the module require firmware updates? A: Firmware is managed at the controller level; the input module itself does not require independent updates.

Field Installation Guidelines

  • Ensure shielded cabling for analog loops to minimize EMI.
  • Maintain separation of digital and analog wiring to reduce cross-talk.
  • Verify DIN rail mounting stability before energizing.
  • Observe environmental limits of -40 to +70 deg C and 5%–95% RH non-condensing.
  • Confirm proper backplane connector alignment to avoid bent pins.