Skip to product information
1 of 3

Honeywell

📢 100% genuine, extensive in-stock inventory, fast shipping!

Honeywell TC-PRR021 51309288-225 Redundancy Module

Honeywell TC-PRR021 51309288-225 Redundancy Module

  • Manufacturer: Honeywell

  • Product No.: TC-PRR021 51309288-225

  • Condition:in Stock

  • Product Type: Redundancy Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 460g

  • Shipping port: Shanghai/Yiwu/Shenzhen

  • Warranty: 12 months

Honeywell TC-PRR021 51309288-225 Redundancy Module

Configured for controller redundancy management in Honeywell Experion PKS networks, the Honeywell TC-PRR021 51309288-225 (TC-PRR021 Redundancy Module) provides direct synchronization and redundancy support between paired C200 and C200E control processors. The module occupies two chassis slots, interfaces through a dedicated redundancy architecture, and enables coordinated processor state management within the control system backplane

Hardware Specifications

Parameter Specification
Model TC-PRR021
Brand Honeywell
Part Number 51309288-225
Product Type Redundancy Module
Compatible Systems Honeywell Experion PKS, C200, C200E
Origin Not specified
Dimensions 7.0 cm x 14.6 cm x 13.3 cm
Weight Approx. 0.46 kg
Operating Temp -40 deg C to +60 deg C
Relative Humidity Up to 95% non-condensing
Power Consumption Not specified
Input Supply Voltage 24 VDC
Input Voltage Range 3.3 VDC to 24 VDC
Current Draw @ 24 VDC 90 mA
Current Draw @ 5.1 VDC 1.0 A
Current Draw @ 3.3 VDC 0.75 A
Current Draw @ 1.2 VDC 7 mA
Slot Requirement 2 chassis slots
Field Connector 36-pin TC-TBCH terminal block
Supported Wire Size 16 AWG to 22 AWG
Compliance CE industrial emissions and immunity standards

Channel-to-Channel Isolation and Redundant Controller Coordination

Within the Experion PKS controller architecture, the TC-PRR021 functions as the redundancy interface between paired control processors. The module manages synchronization data exchange and status communication required for coordinated processor operation.

Redundant controller configurations depend on deterministic communication between primary and secondary processors. Proper installation of the redundancy module and associated field wiring helps maintain synchronization integrity during processor state transitions and maintenance activities. Separation of communication wiring from high-energy power conductors assists in minimizing externally induced electrical interference.

Frequently Asked Questions

Q: How many chassis slots are required for the TC-PRR021?
A: The module occupies two chassis slots within the Honeywell control chassis.

Q: What field termination assembly is used with the module?
A: The supplied documentation specifies a 36-pin TC-TBCH field wiring connector.

Q: Can the module be used with C200 and C200E controllers?
A: Yes. The available specifications identify compatibility with Honeywell Experion PKS C200 and C200E control systems.

Field Installation Guidelines

  • De-energize the chassis before installing or removing the redundancy module.

  • Verify that the selected chassis location matches the controller redundancy configuration requirements.

  • Confirm compatibility between controller firmware revisions before commissioning a redundant processor pair.

  • Ensure the module is fully seated into the backplane connector before applying power.

  • Route redundancy communication wiring separately from AC power conductors and motor control circuits.

View full details