WOODWARD
📢 100% genuine, extensive in-stock inventory, fast shipping!
Woodward 9905-002 2301A High Voltage Speed Controller
Woodward 9905-002 2301A High Voltage Speed Controller
Manufacturer: WOODWARD
-
Product No.: 9905-002
Condition:in Stock
Product Type: 9905-002
-
Product Origin: USA
Payment:T/T, Western Union
-
Weight: 1360g
Shipping port: Shanghai/Yiwu/Shenzhen
Warranty: 12 months
Share
Overview
The 9905-002 is a high-voltage powered governor module from the Woodward 2301A control family, developed for engine-driven generator applications. Unlike low-voltage variants, the 9905-002 operates directly from AC or high-level DC sources, making it suitable for installations where 24 VDC is not available.
This unit continuously interprets speed signals from a magnetic pickup and adjusts actuator current output to regulate fuel delivery. It ensures stable frequency control and coordinated load distribution across parallel generator systems.
Technical Specifications
| Parameter | Details |
|---|---|
| Model | 9905-002 |
| Product Series | 2301A Load Sharing & Speed Control |
| Supply Voltage | 88–132 VAC or 90–150 VDC |
| Speed Input | Magnetic Pickup (1–30 Vrms) |
| Frequency Range | 500 to 12,000 Hz |
| Actuator Output | 0–200 mA |
| Power Consumption | 10–15 W |
| Operating Temperature | -40°C to +70°C |
| Mounting Style | Chassis Mount (Sheet Metal Housing, IP20) |
Functional Description
The 9905-002 acts as the central control element in an electronic governing system. It compares actual engine speed against a reference setpoint and dynamically adjusts actuator output to maintain the desired operating condition.
Its control strategy is based on a PID loop, enabling stable performance even under rapid load fluctuations.
Key Features
Flexible Operating Modes
Supports both isochronous and droop configurations. Isochronous mode maintains constant speed regardless of load changes, while droop mode enables controlled frequency variation for parallel generator operation.
Integrated Load Sharing Capability
Includes dedicated load-sharing interfaces that allow multiple controllers to exchange load signals. This ensures balanced kW distribution across generators and prevents uneven loading conditions.
Remote Speed Adjustment
Provides an input for an external potentiometer, allowing operators to fine-tune engine speed from a control panel without direct access to the module.
Stable Actuator Drive Output
The 0–200 mA analog output is optimized for Woodward actuators, delivering precise and consistent fuel control across different engine types.
Control Tuning and Dynamics
The controller allows manual adjustment of dynamic response parameters:
-
Gain: Defines proportional sensitivity to speed deviations
-
Reset: Eliminates steady-state offset through integral action
-
Actuator Compensation: Matches output behavior to actuator response characteristics
These parameters enable fine tuning for various engine sizes and fuel systems, minimizing oscillation and improving stability.
Application Areas
The 9905-002 is commonly deployed in:
-
Diesel and gas generator sets
-
Industrial turbine auxiliary systems
-
Power plant control panels
-
Retrofit projects replacing mechanical or legacy governors
It is particularly useful in facilities where higher voltage supplies are standard.
Comparison with 9905-211
Although both belong to the same 2301A platform, their power requirements differ:
-
9905-002: High-voltage AC/DC input
-
9905-211: Low-voltage 24 VDC input
Performance and control capabilities remain consistent across both models, with selection driven by available power infrastructure.
FAQ
What type of sensor is required for speed input?
A magnetic pickup sensor is required, providing a frequency signal proportional to shaft rotation.
Can this unit control multiple generators in parallel?
Yes, when connected through load-sharing lines, it enables coordinated load distribution across multiple units.
Is it suitable for retrofit applications?
Yes, it is widely used to upgrade older governing systems to modern electronic control.
What safety precautions are required?
Due to high-voltage operation, proper grounding is mandatory. Always isolate power before performing wiring or configuration changes.